Gantry Maintenance

Gantry

Equalize and synchronize the gantry

  • It is possible for the gantry to become twisted such that is not perpendicular to the tracks.

  • This is usually caused by an obstruction on one track that stalls that side of the gantry and misaligns the system, or a loose belt on one track.

  • If a belt is loose, tighten according to these instructions.

  • If the belts are tight and the gantry is twisted, re-equalize and synchronize the gantry using instructions on the gantry page.


Cross-Slide

Inspect the delrin leadscrew block

  • Over time, it is possible for the delrin leadscrew block to wear down.

  • This can introduce play into the system that decreases z-axis precision, which can cause issues with the mounting and dismounting of tools.


Z-Axis

Clean and lubricate the leadscrew

  • The z-axis leadscrew will become dirty after being outside for a prolonged period of time.

  • Excessive dirt and grime on the leadscrew can cause premature wear, a loss of precision, and missed steps if not addressed.